Features

  • automatic polarity function
  • low-battery indication
  • transistor and diode test
  • voltage measurements: AC 500 V and DC 500 V max.
  • current measurements: max. 10 A
  • resistance measurements: max. 2 Mohm
  • packaging: blister
  • CAT. II 500 V
  • Important safety information

Specifications

  • DC voltage: 200 m/2000 m/20/200/500 V
    • basic accuracy: ± 0.5% of rdg ± 2 digits for 0.2V range / ± 0.8% of rdg ± 2 digits for 2V~200V range / ± 1.0% of rdg ± 2 digits for 500V range
    • input impedance: -
    • maximum input: 500 V
  • AC voltage: 200/500 V
    • basic accuracy: ± 1.5% of rdg ± 10 digits
    • input impedance: -
    • frequency range: 45-450 Hz
    • maximum input: 500 V
  • DC current: 2000 µ/20 m/200 m/10 A
    • basic accuracy: ± 1.2% of rdg ± 2 digits for 2000µ~20mA range / ± 1.5% of rdg ± 2 digits for 200mA range / ± 2.5% of rdg ± 2 digits for 10A range
    • overload protection: 500 mA/250 V resettable fuse + 10 A/250 V fuse
  • AC current: -
    • basic accuracy: -
    • overload protection: -
  • resistance: 200/2000/20 k/200 k/2000 k
    • basic accuracy: ± 0.8% of rdg ± 2 digits for 200~200K range / ± 1.2% of rdg ± 2 digits for 2000K range
    • overload protection: 220Vrms max. for 15 seconds
  • capacitance: -
    • accuracy: -
  • inductance: -
    • accuracy: -
  • frequency: -
    • basic accuracy: -
    • overload protection: -
  • temperature: -
    • basic accuracy: -
  • overrange: yes "1"
  • continuity buzzer: yes
  • transistor test: yes
  • diode test: yes
  • low-battery indication: yes
  • maximum display: 1999
  • LCD display size: -
  • ranging mode: manual
  • data hold: no
  • backlight: no
  • dimensions: 126 x 70 x 27 mm
  • weight (with battery): ±120 g
  • power supply: 2 x AAA (LR03C, incl.)
  • packing: blister
  • accessories: manual / test leads / battery
  • auto power-off: -